@@ -0,0 +1,37 @@
|
|||||||
|
# Motorola 6809 and TI SN74LS612 Timing
|
||||||
|
|
||||||
|
## Motorola 6809 Timing
|
||||||
|
Dual phase clock, E and Q. Staggered by half a clock.
|
||||||
|
1, 1.5, or 2 mHz. Nanosecond timing will be listed for all 3 speeds.
|
||||||
|
|
||||||
|
* On Q rise, address and R/-W output is valid.
|
||||||
|
* On E rise, data output is valid.
|
||||||
|
* Time between Q rise and E rise is (approx) minimum 200/130/80ns and max 250/166/125ns.
|
||||||
|
* Time between address and R/-W output to data output.
|
||||||
|
* On E fall, data input is read. Address and R/-W output become invalid.
|
||||||
|
* Data input must be valid for minimum 80/60/40ns before E fall.
|
||||||
|
* Output data on Q fall to ensure data input is valid.
|
||||||
|
|
||||||
|
## TI SN74LS612 Timing
|
||||||
|
Async
|
||||||
|
|
||||||
|
### Write mode:
|
||||||
|
|
||||||
|
* -Strobe occurs to perform write.
|
||||||
|
* -Strobe pulse must be at least 75ns.
|
||||||
|
* Data must be valid 75ns before -strobe fall.
|
||||||
|
* -CS, R/-W, RS must be low at least 20ns before -strobe fall.
|
||||||
|
* -CS, R/-W, RS, Data must be valid at least 20ns after -strobe rise.
|
||||||
|
|
||||||
|
## Interface
|
||||||
|
|
||||||
|
### 6809 Write to SN74LS612
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
## Sources
|
||||||
|
|
||||||
|
* Motorola MC6809 Datasheet, undated
|
||||||
|
* Motorola MC6809E Datasheet, 1984
|
||||||
|
* TI SN54LS610, SN54LS612, SN74LS610 THRU SN74LS613 Datasheet, 1981-1988
|
Reference in New Issue